ASTM C1556 PDF

This standard is issued under the fixed designation C ; the number immediately 1 This test method is under the jurisdiction of ASTM Committee C09 on. ASTM Ca(). Standard Test Method for Determining the Apparent Chloride Diffusion Coefficient of Cementitious Mixtures by Bulk. Download Table | ASTM C Chloride Bulk Diffusion Test Results from publication: Decreasing the Clinker Component in Cementing Materials: Performance.

Author: Doukora Fenrilrajas
Country: Antigua & Barbuda
Language: English (Spanish)
Genre: Love
Published (Last): 4 March 2018
Pages: 489
PDF File Size: 11.87 Mb
ePub File Size: 12.94 Mb
ISBN: 498-6-99811-398-8
Downloads: 93921
Price: Free* [*Free Regsitration Required]
Uploader: Tojasida

Link to Active This link will always route to the current Active version of the standard. ASTM C states that each sample consists of at least two 2 specimens.

Client must specify the exposure age, water cementitious ratio and if a pozzolan or slag has been used as it is required to modify the depth intervals as specified in ASTM C’s Recommended Depth Interval Table.

Order Form 2 Email complete form to contact listed below.

Print and complete the following order form. This calculation procedure is not applicable to specimens exposed to chloride ions during cyclic wetting and drying.

ASTM C1556: “Apparent Chloride Diffusion Coefficient of Cementitious Mixtures”

Use The apparent chloride diffusion coefficient is used to estimate chloride penetration into cementitious mixtures that are in a saturated condition. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

If you need more info or have any questions, please note the Lab ID number and contact us at:. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as asrm of the standard.

ASTM C Apparent Chloride Diffusion Coefficient | CTLGroup

Therefore, apparent diffusion coefficients obtained at early ages may not be representative of performance in service. Historical Version s – view previous versions of standard.

If you need more info or have any questions, c155 note the Lab ID number and contact us at: No other units of measurement are included in this standard. The calculation procedure described in C is only applicable to specimens exposed to a sodium chloride solution as described in C, not to specimens exposed to chloride ions during cyclic wetting and drying.

Time for Results Please contact a CTLGroup chemical services representative or Project Manager to discuss your individual asrm needs and testing response times.

Results Produced The apparent chloride diffusion coefficient.

Instructions The sample specimens may be cores, cylinders, or cubes. The rate of change x1556 the apparent diffusion coefficient for cementitious mixtures containing pozzolans or blast-furnace slag is typically different than that for mixtures containing only portland cement.

Privacy Policy Sensors Sitemap.

The apparent diffusion coefficient determined by this method includes bound chloride, so proper use of the apparent chloride diffusion coefficient to predict chloride ingress requires consideration of chloride binding.

The concentration and valence of other ionic species in the pore fluid also influence the rate of chloride diffusion, and therefore, the apparent diffusion coefficient as determined by this test procedure. The diffusion of ionic species in concrete occurs within the fluid-filled pores, cracks and void spaces.

This article was written by admin