ASTM F2170-11 PDF

ASTM F formally recognizes the use of in situ probes as a means of conducting relative humidity testing. In fact, ASTM F represents a fundamental. Last previous edition approved in as. F DOI: / F/FA. 2 For referenced ASTM standards, visit the ASTM . ASTM F ASTM F RH (Relative Humidity) DOI: /F The ASTM F standard represents a fundamental change in how moisture is.

Author: Kazralkis Junris
Country: Grenada
Language: English (Spanish)
Genre: Science
Published (Last): 24 October 2016
Pages: 302
PDF File Size: 14.70 Mb
ePub File Size: 12.49 Mb
ISBN: 522-3-19704-116-4
Downloads: 21679
Price: Free* [*Free Regsitration Required]
Uploader: Meztinos

Use our checklist to record and report the RH readings. This site uses Akismet to reduce spam. Check job site conditions. In celebration of the New Year, we will be closing early at Operation is that easy! In this way, in situ measurement provides a composite picture of overall slab moisture levels, and provides the data necessary to make business decisions regarding flooring installations.

These first five steps are all preparatory and should be done before any sensors or RH probes are installed. First, I have to state that F is specified for interior applications that asttm under consistent ambient air controls.

Each hole must have a liner that isolates the f2170–11 from ambient conditions, and sensors must have NIST-traceable calibration. In-situ probes deepen concrete moisture measurement. September 6, at June 8, at 1: For most RH testing systems, this includes cleaning any debris out of the test hole and inserting the necessary liner in the hole.

For extended reach, a cable up to 50ft long can be added.

Concrete absorbs water vapor from the air under high ambient humidity; concrete releases more water vapor when the humidity of the surrounding air is low. April 7, at 3: At this point, if one test fails, they all fail. It has been believed that the change in the desiccant weight could be translated into a moisture ratio for the concrete beneath.

  LRY-517 MANUAL PDF

Concrete slab moisture problems can cause floor covering delamination, peeling, blistering, staining and sweating. This process requires time and quantifiable concrete moisture measurements to verify. September 2, at 9: And installers are finding results are more accurate and more dependable with RH testing.

Many contractors use vapor barriers directly under the slab to slow moisture permeation.

Ligno-Tec RH Concrete Test Conforms to ASTM F

Reusable sensors should be calibrated by the manufacturer at least once per year, or more often if exposed to conditions that may impact their accuracy. Asstm flooring and concrete professionals, ASTM F provides the standard for using relative humidity RH testing when measuring moisture content in concrete slabs. In that case, builders did not allow the slab sufficient time for concrete moisture levels to equilibrate reach equilibrium moisture content according to relative humidity RH.

Learn how your comment data is processed. Concrete slab moisture is a major cause of concrete flooring failure.

Ligno-Tec RH Concrete Moisture Meter

The instruments have proven to perform well in rough mill environments with day-to-day usage. Contact My Account 0 items And moisture can still be an issue at grade so concrete foundations must be designed to include proper moisture drainage.

That being said, there are many people that have used F testing methodology for testing roof decks with this understanding. UPS peak season may cause delays.

  BUXHETI KOSOVES 2010 PDF

October 27, at If longer sleeves are desired we also offer 3. In situ moisture measurement systems are evolving rapidly as a result of ATSM F and reflect the industry realities of the concrete installation business.

c2170-11

Without studying pages and pages of operation manuals: Is this acceptable or compromise the test? At any time you can change from pin mode to scan f1270-11 by depressing up or down button.

Jason, I appreciate this means to contact you. Know the required depth of the test holes.

ASTM F Explained – ASTM F Information

Each test hole must be drilled to the depth determined at Step 5 above section 10 of ASTM F and properly prepared. ASTM F formally recognizes the use of in situ probes as a means of conducting relative humidity testing. Make sure your calibration is up to date. After the initial reading, readings can be updated at any time desired g2170-11 two conditions in mind: To check the calibration we offer calibration check salts.

10 Guidelines for ASTM F2170 Preparation and Testing

This website uses cookies. The RH BluePeg probe drops easily into the sleeve. The Ligno-Tec RH was t2170-11 for reliability and accuracy as well as sturdiness and ease of operation. These requirements for the standard apply regardless of the RH test method being used. Note that the liner requirements have been updated and the hole is to be fully lined to meet the ASTM standard.

This article was written by admin